{"id":2750,"date":"2024-11-14T12:34:16","date_gmt":"2024-11-14T12:34:16","guid":{"rendered":"http:\/\/www.baghouse.com\/?p=2750"},"modified":"2025-05-06T20:03:27","modified_gmt":"2025-05-06T20:03:27","slug":"how-to-maintain-and-operate-your-dust-collector-using-differential-pressure","status":"publish","type":"post","link":"https:\/\/baghouse.com\/es\/how-to-maintain-and-operate-your-dust-collector-using-differential-pressure\/","title":{"rendered":"C\u00f3mo operar y mantener tu colector de polvo usando la presi\u00f3n diferencial"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2750\" class=\"elementor elementor-2750\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-26a1e31e e-flex e-con-boxed e-con e-parent\" data-id=\"26a1e31e\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-93ffe97 elementor-widget elementor-widget-text-editor\" data-id=\"93ffe97\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div id=\"attachment_25138\" style=\"width: 229px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.powderbulksolids.com\/dust-collection\/how-to-maintain-operate-dust-collectors-using-differential-pressure\"><img fetchpriority=\"high\" decoding=\"async\" aria-describedby=\"caption-attachment-25138\" class=\"wp-image-25138 size-medium\" src=\"https:\/\/www.baghouse.com\/wp-content\/uploads\/2024\/11\/Powder-Bulk-Solids-Magazine-219x300.png\" alt=\"Powder &amp; Bulk Solids Magazine Cover\" width=\"219\" height=\"300\" srcset=\"https:\/\/baghouse.com\/wp-content\/uploads\/2024\/11\/Powder-Bulk-Solids-Magazine-219x300.png 219w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/11\/Powder-Bulk-Solids-Magazine-450x616.png 450w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/11\/Powder-Bulk-Solids-Magazine.png 472w\" sizes=\"(max-width: 219px) 100vw, 219px\" \/><\/a><p id=\"caption-attachment-25138\" class=\"wp-caption-text\">Portada de la revista Powder &amp; Bulk Solids<\/p><\/div><p>Este art\u00edculo fue publicado por baghouse.com en la edici\u00f3n de enero de 2025 de la revista <a href=\"https:\/\/www.powderbulksolids.com\/\">Revista Powder Bulk &amp; Solids<\/a>. Tambi\u00e9n puedes leerlo en este enlace:<\/p><h3><strong><a href=\"https:\/\/www.powderbulksolids.com\/dust-collection\/how-to-maintain-operate-dust-collectors-using-differential-pressure\">C\u00f3mo Mantener y Operar Colectores de Polvo Usando la Presi\u00f3n Diferencial<\/a><\/strong><\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-840ea91 elementor-widget elementor-widget-text-editor\" data-id=\"840ea91\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div id=\"attachment_24801\" style=\"width: 310px\" class=\"wp-caption alignright\"><img decoding=\"async\" aria-describedby=\"caption-attachment-24801\" class=\"size-medium wp-image-24801\" src=\"https:\/\/www.baghouse.com\/wp-content\/uploads\/2024\/10\/Image-1-300x168.png\" alt=\"Baghouse.com personnel monitoring the differential pressure in a cartridge collector\" width=\"300\" height=\"168\" srcset=\"https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-1-300x168.png 300w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-1-1030x576.png 1030w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-1-768x430.png 768w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-1-705x394.png 705w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-1-450x252.png 450w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-1.png 1500w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-24801\" class=\"wp-caption-text\">Monitorear regularmente la presi\u00f3n diferencial nos dar\u00e1 informaci\u00f3n sobre c\u00f3mo est\u00e1 operando nuestro sistema.<\/p><\/div><p>La presi\u00f3n diferencial es el dato clave que se utiliza para determinar c\u00f3mo est\u00e1 funcionando un colector de polvo. Monitorear esta variable es como revisar la presi\u00f3n arterial en el cuerpo humano. <strong><em>As\u00ed como la presi\u00f3n arterial indica la salud y eficiencia del sistema circulatorio, la presi\u00f3n diferencial ofrece una medici\u00f3n vital de qu\u00e9 tan bien est\u00e1 funcionando el colector de polvo.<\/em><\/strong><\/p><p>Los operadores del sistema y los t\u00e9cnicos de mantenimiento deben vigilar de cerca <a href=\"https:\/\/baghouse.com\/es\/baghouse-differential-pressure-why-important\/\">la presi\u00f3n diferencial<\/a> en todo momento para garantizar el correcto funcionamiento del sistema. Tambi\u00e9n deben monitorearla para planificar el mantenimiento y realizar cualquier modificaci\u00f3n al sistema, como aumentar la capacidad o mejorar la eficiencia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38e4b50 elementor-widget elementor-widget-spacer\" data-id=\"38e4b50\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a82ed59 elementor-widget elementor-widget-heading\" data-id=\"a82ed59\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Lo que la presi\u00f3n diferencial nos dice...<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0f7ed11 elementor-widget elementor-widget-text-editor\" data-id=\"0f7ed11\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><strong>...Sobre los filtros de su colector de polvo<\/strong><\/h2><p><strong>\u00a0<\/strong><\/p><div id=\"attachment_24802\" style=\"width: 438px\" class=\"wp-caption alignright\"><img decoding=\"async\" aria-describedby=\"caption-attachment-24802\" class=\"wp-image-24802\" src=\"https:\/\/www.baghouse.com\/wp-content\/uploads\/2024\/10\/Image-2-300x212.png\" alt=\"dust cake in a dust collector filter\" width=\"428\" height=\"303\" srcset=\"https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-2-300x212.png 300w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-2-1030x728.png 1030w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-2-768x543.png 768w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-2-1536x1086.png 1536w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-2-2048x1448.png 2048w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-2-1500x1060.png 1500w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-2-260x185.png 260w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-2-705x498.png 705w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-2-450x318.png 450w\" sizes=\"(max-width: 428px) 100vw, 428px\" \/><p id=\"caption-attachment-24802\" class=\"wp-caption-text\">Los filtros obstruidos por largo tiempo con una gran capa de polvo tendr\u00e1n un mayor nivel de fugas.<\/p><\/div><p><strong>\u25cf Si la presi\u00f3n diferencial es alta<\/strong><\/p><ul><li>\u25cb\u00a0Una presi\u00f3n diferencial consistentemente alta es una se\u00f1al de que los filtros est\u00e1n obstruidos (es decir, el tejido est\u00e1 completamente saturado de part\u00edculas de polvo). Una vez obstruidos, los filtros ya no pueden ser limpiados y <a href=\"https:\/\/baghouse.com\/es\/how-often-should-baghouse-filters-be-changed\/\">deben ser reemplazados.<\/a><\/li><li>\u25cb Los filtros obstruidos o incluso los filtros con una gran acumulaci\u00f3n temporal de polvo tendr\u00e1n mayores emisiones (es decir, fugas). Verifique los niveles de emisiones con medidores de opacidad o <a href=\"https:\/\/baghouse.com\/es\/find-leaking-baghouse-filters-faster-with-a-triboelectric-broken-bag-detector\/\">detectores de bolsas rotas<\/a> .<\/li><li><a href=\"https:\/\/baghouse.com\/es\/how-to-avoid-undersizing-a-baghouse-dust-collection-system\/\">Una relaci\u00f3n aire-tejido insuficiente<\/a> para la aplicaci\u00f3n resultar\u00e1 en bolsas sobrecargadas de polvo y el sistema de limpieza no podr\u00e1 limpiar las bolsas de manera efectiva.<\/li><\/ul><p><strong>\u25cf Si la presi\u00f3n diferencial es baja<\/strong><\/p><ul><li>\u25cb Una presi\u00f3n diferencial anormalmente baja (por debajo de 3\u2033) puede ser se\u00f1al de agujeros, desgarros o costuras sueltas en las bolsas o de que los filtros no est\u00e1n instalados correctamente (banda de sujeci\u00f3n desalineada en modelos de carga superior, abrazaderas de bolsa sueltas en unidades de carga inferior).<\/li><\/ul><h2>\u00a0<\/h2><h2><strong>\u2026Sobre su sistema de limpieza<\/strong><\/h2><p>\u00a0<\/p><div id=\"attachment_24803\" style=\"width: 235px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-24803\" class=\"size-medium wp-image-24803\" src=\"https:\/\/www.baghouse.com\/wp-content\/uploads\/2024\/10\/Image-3-225x300.jpg\" alt=\"blinded pleated filters\" width=\"225\" height=\"300\" srcset=\"https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-3-225x300.jpg 225w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-3-773x1030.jpg 773w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-3-768x1024.jpg 768w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-3-1152x1536.jpg 1152w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-3-1536x2048.jpg 1536w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-3-1125x1500.jpg 1125w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-3-529x705.jpg 529w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-3-450x600.jpg 450w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-3-scaled.jpg 1920w\" sizes=\"(max-width: 225px) 100vw, 225px\" \/><p id=\"caption-attachment-24803\" class=\"wp-caption-text\">Una limpieza deficiente de las bolsas resultar\u00e1 en mayor presi\u00f3n diferencial (DP), ya que la capa de polvo se acumular\u00e1 m\u00e1s r\u00e1pido de lo que se puede limpiar<\/p><\/div><p><strong>\u25cf Si la presi\u00f3n diferencial es alta<\/strong><\/p><ul><li>\u25cb Una limpieza inadecuada de las bolsas resultar\u00e1 en una presi\u00f3n diferencial m\u00e1s alta, ya que el polvo se acumular\u00e1 m\u00e1s r\u00e1pido de lo que se puede limpiar.<\/li><li>\u25cb En un colector de polvo que usa pulso de aire comprimido, esto puede ser causado por baja presi\u00f3n de aire comprimido, aire contaminado (suciedad, agua o aceite en el reservorio de aire), tubos de soplado mal alineados o venturis de jaula mal alineados o faltantes.<\/li><li>\u25cb Si los ciclos de limpieza (es decir, los pulsos de aire) no est\u00e1n configurados correctamente, las bolsas no se limpiar\u00e1n adecuadamente. (\u201cOn Time\u201d es el tiempo durante el cual la v\u00e1lvula de aire comprimido est\u00e1 abierta. Si est\u00e1 configurada con demasiado tiempo de apertura, el estallido de aire ser\u00e1 demasiado d\u00e9bil para limpiar la bolsa. Si est\u00e1 configurado con poco tiempo de apertura, no liberar\u00e1 suficiente aire para limpiar toda la longitud de la bolsa).<\/li><li>\u25cb El orden en que se limpian las bolsas (llamado \u201csecuencia de disparo\u201d) debe estar escalonado (1, 4, 2, 5, 3, 6) para que las filas sucesivas no se limpien una tras otra (por ejemplo, 1, 2, 3, 4, 5, 6).<\/li><\/ul><p><strong>\u00a0<\/strong><\/p><p><strong>\u25cf Si la presi\u00f3n diferencial es baja<\/strong><\/p><ul><li><div id=\"attachment_24804\" style=\"width: 310px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-24804\" class=\"size-medium wp-image-24804\" src=\"https:\/\/www.baghouse.com\/wp-content\/uploads\/2024\/10\/Image-4-300x225.png\" alt=\"Holes in a dust collector filter bag\" width=\"300\" height=\"225\" srcset=\"https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-4-300x225.png 300w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-4-1030x773.png 1030w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-4-768x577.png 768w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-4-705x529.png 705w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-4-450x338.png 450w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-4.png 1428w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-24804\" class=\"wp-caption-text\">Trabajar con un excesivo aire comprimido causar\u00e1 un fallo prematuro de las bolsas, a menudo creando problemas de abrasi\u00f3n o incluso provocando agujeros en el material<\/p><\/div>\u25cb La limpieza excesiva de las bolsas provocar\u00e1 un desgaste innecesario de los filtros y llevar\u00e1 a fallos prematuros.<\/li><li>\u25cb Si la presi\u00f3n del aire comprimido es demasiado alta limpiar\u00e1 mejor los filtros, tambi\u00e9n causar\u00e1 un fallo prematuro del filtro, creando a menudo problemas de abrasi\u00f3n o incluso agujeros en el tejido.<\/li><li>\u25cb Dado que las emisiones son m\u00e1s altas cuando se pulsan los filtros, un exceso de pulsos lleva a un aumento de las emisiones.<\/li><\/ul><h2>\u00a0<\/h2><h2><strong>\u2026Sobre problemas con su sistema de recolecci\u00f3n de polvo<\/strong><\/h2><p><strong>\u25cf Si la presi\u00f3n diferencial es alta<\/strong><\/p><ul><li>\u25cb Los cambios repentinos en la presi\u00f3n diferencial pueden ser causados por condiciones inesperadas o cambios en el proceso que el sistema est\u00e1 ventilando. Cualquier problema en el colector de polvo podr\u00eda ser se\u00f1al de que algo potencialmente m\u00e1s serio est\u00e1 ocurriendo m\u00e1s arriba del equipo.<\/li><li>\u25cb Una presi\u00f3n diferencial consistentemente alta podr\u00eda ser se\u00f1al de que el sistema est\u00e1 subdimensionado y no puede soportar la carga que se le est\u00e1 colocando.<\/li><li>\u25cb Las placas deflectoras desgastadas, las cajas de ca\u00edda y un dise\u00f1o de flujo de aire deficiente conducen a la sobrecarga de los filtros y a una presi\u00f3n diferencial alta.<\/li><li>\u25cb Una acumulaci\u00f3n excesiva de polvo en la tolva puede llevar a la reentrada de polvo y sobrecargar los filtros.<\/li><li>\u25cb El polvo h\u00famedo o pegajoso, que es dif\u00edcil de limpiar, puede ser se\u00f1al de fugas cerca de las compuertas o grietas en la estructura del baghouse que permiten que entre humedad o aire fr\u00edo, causando condensaci\u00f3n en los filtros.<\/li><\/ul><p><strong>\u25cf Si la presi\u00f3n diferencial es baja<\/strong><\/p><ul><li>\u25cb Las grietas o agujeros en la estructura o en la placa tubular del colector de polvo pueden causar una reducci\u00f3n significativa en la presi\u00f3n diferencial y llevar a un gran aumento de las emisiones.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55db7e4 elementor-widget elementor-widget-spacer\" data-id=\"55db7e4\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fdcca87 elementor-widget elementor-widget-heading\" data-id=\"fdcca87\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00a1Cuidado con las mediciones incorrectas!<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e608474 elementor-widget elementor-widget-text-editor\" data-id=\"e608474\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div id=\"attachment_24805\" style=\"width: 365px\" class=\"wp-caption alignright\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-24805\" class=\"wp-image-24805\" src=\"https:\/\/www.baghouse.com\/wp-content\/uploads\/2024\/10\/Image-5-225x300.jpg\" alt=\"Magnehelic pressure gauge\" width=\"355\" height=\"473\" srcset=\"https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-5-225x300.jpg 225w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-5-773x1030.jpg 773w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-5-768x1024.jpg 768w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-5-529x705.jpg 529w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-5-450x600.jpg 450w, https:\/\/baghouse.com\/wp-content\/uploads\/2024\/10\/Image-5.jpg 1125w\" sizes=\"(max-width: 355px) 100vw, 355px\" \/><p id=\"caption-attachment-24805\" class=\"wp-caption-text\">Si los operadores tienen lecturas incorrectas, podr\u00eda resultar en da\u00f1os al sistema, un aumento de las emisiones o incluso en riesgos de incendio y polvo combustible<\/p><\/div><p>Si los operadores tienen lecturas incorrectas, esto podr\u00eda resultar en da\u00f1os al sistema, aumento de emisiones o incluso riesgos de incendio y polvo combustible. <a href=\"https:\/\/baghouse.com\/es\/baghouse-differential-pressure-how-to-troubleshoot-false-readings\/\">Como se mencion\u00f3 en art\u00edculos anteriores, es vital asegurarse de que las lecturas de la presi\u00f3n diferencial provenientes de la unidad sean precisas.<\/a>Para ello, es mejor hacer del mantenimiento de las l\u00edneas de aire, man\u00f3metros y controladores una <a href=\"https:\/\/baghouse.com\/es\/baghouse-differential-pressure-why-important\/\">parte regular del programa de mantenimiento preventivo del colector de polvo.<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73af4ea elementor-widget elementor-widget-spacer\" data-id=\"73af4ea\" data-element_type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-533f9d9 elementor-widget elementor-widget-heading\" data-id=\"533f9d9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusi\u00f3n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c00eaf elementor-widget elementor-widget-text-editor\" data-id=\"5c00eaf\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>\u00bfCu\u00e1ntas decisiones de mantenimiento y operaci\u00f3n relacionadas con su colector de polvo o baghouse est\u00e1n influenciadas por la presi\u00f3n diferencial?\u00a0<\/p><h2>\u00a1Todas!<\/h2><h3>\u00a0<\/h3><h3>\u00a0<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-960a9d6 elementor-widget elementor-widget-text-editor\" data-id=\"960a9d6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>\u00bfTiene preguntas sobre la presi\u00f3n diferencial? \u00bfTiene lecturas extra\u00f1as y no est\u00e1 seguro de qu\u00e9 significan? \u00a1Por favor, ll\u00e1menos o env\u00edenos un correo a info@baghouse.com y perm\u00edtanos ver c\u00f3mo podemos ayudarle!<\/h3>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-39ab1b5 elementor-align-center elementor-widget elementor-widget-button\" data-id=\"39ab1b5\" data-element_type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/baghouse.com\/es\/contact\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u00a1Habla con un experto!<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-499f9c5 e-flex e-con-boxed e-con e-parent\" data-id=\"499f9c5\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>This article was published in the January 2025 Edition of the Magazine Powder Bulk &amp; Solids. You can also read it in this link: How to Maintain &amp; Operate Dust Collectors Using Differential Pressure Differential pressure is the key data metric used to determine how a dust collector is operating.\u00a0 Monitoring this variable is like [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":25132,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[30,61],"tags":[516,410,38,71,524,430,522,259,513,221,201,60,517,62,396,452,514,523,187,236,518,525,207,519,515,521,526,189,520],"class_list":["post-2750","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-dust-collection-blog","category-dust-collector-troubleshooting","tag-air-pressure","tag-air-to-cloth-ratio","tag-baghouse","tag-baghouse-filters","tag-baghouse-operation","tag-baghouse-performance","tag-broken-bag-detectors","tag-differential-pressure","tag-dust-cake","tag-dust-collection-systems","tag-dust-collector-filters","tag-dust-collector-maintenance","tag-dust-collector-problems","tag-dust-collector-troubleshooting","tag-dust-control","tag-dust-control-solutions","tag-emissions-control","tag-filter-bag-wear","tag-filter-cleaning","tag-filter-replacement","tag-high-pressure","tag-industrial-air-quality","tag-industrial-dust-collection","tag-low-pressure","tag-maintenance-technicians","tag-opacity-meters","tag-preventive-maintenance","tag-pulse-jet-dust-collector","tag-system-efficiency"],"acf":[],"_links":{"self":[{"href":"https:\/\/baghouse.com\/es\/wp-json\/wp\/v2\/posts\/2750","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/baghouse.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/baghouse.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/baghouse.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/baghouse.com\/es\/wp-json\/wp\/v2\/comments?post=2750"}],"version-history":[{"count":0,"href":"https:\/\/baghouse.com\/es\/wp-json\/wp\/v2\/posts\/2750\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/baghouse.com\/es\/wp-json\/wp\/v2\/media\/25132"}],"wp:attachment":[{"href":"https:\/\/baghouse.com\/es\/wp-json\/wp\/v2\/media?parent=2750"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/baghouse.com\/es\/wp-json\/wp\/v2\/categories?post=2750"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/baghouse.com\/es\/wp-json\/wp\/v2\/tags?post=2750"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}